Locking out robots, VFDs, and servo systems means controlling every energy source, including stored electrical, pneumatic, hydraulic, and gravity energy, because a stop button, guard interlock, or software state may not control them all.
Hazards and isolation methods depend on the specific equipment and task. This guide lists topics to review with qualified site personnel and the manufacturer; it does not give instructions for isolating, testing, or entering a particular machine or robot cell.
Why automation changes the energy picture
For covered servicing, 1910.147 applies where unexpected energization, start-up, or release of stored energy could injure employees, subject to the standard’s scope and exceptions. Automated equipment may have energy sources that are not controlled by a single disconnect. Identify them through the employer’s documented assessment and the equipment-specific procedure.
Use the energy assessment guide as a documentation aid. Qualified site personnel must determine the actual energy sources and approved isolation and verification methods for the machine and task.
VFDs and drives: the DC bus that outlives the disconnect
Drives and other electrical equipment may retain hazardous electrical energy after a source is disconnected. The discharge characteristics and verification method depend on the specific equipment and manufacturer instructions. Treat these as electrical work requiring the employer’s approved procedure and qualified personnel.
- Identify the drive, auxiliary supplies, stored electrical energy, and manufacturer-specified discharge and testing requirements in the employer’s assessment.
- Do not rely on a generic waiting period or online instructions to decide that conductors are safe to touch.
- Have qualified personnel determine the isolation boundaries and any test method under the employer’s electrical safety procedures and applicable rules.
- Document only the equipment-specific method approved by the employer; this article does not specify a voltage threshold or test sequence.
Robots and servo axes: gravity, brakes, and stored air
Robots and servo systems may involve gravity, mechanical restraint, pneumatic energy, brakes, and other hazards. A programmed position, emergency stop, teach mode, or interlock does not by itself establish that hazardous energy is controlled for servicing.
- Have qualified personnel identify the manufacturer’s servicing instructions, the employer-approved energy-control procedure, and any task-specific electrical or machine-safety requirements.
- The employer’s assessment must account for hazardous motion, gravity, mechanical restraint, and stored energy relevant to the work.
- Do not enter a cell or rely on a pose, brake, test mode, or control setting based on generic web guidance.
Capacitors, batteries, and backup power
Capacitors, UPS equipment, batteries, and auxiliary power may present hazards that are not controlled by the primary disconnect. Identify applicable sources in the energy assessment and use qualified personnel and the manufacturer’s instructions to determine the site-approved controls.
- Confirm whether auxiliary power or backup supplies are within the scope of the employer’s procedure; do not assume a primary disconnect controls them.
- Consider control circuits, stored electrical energy, and pneumatic or mechanical actuation where they are relevant to the actual machine and work.
- Document and verify controls using the equipment-specific method approved by the employer and performed by appropriately qualified personnel.
Interlocks are not lockout
Control-circuit devices such as push buttons, selector switches, and interlocks are not energy-isolating devices as defined in 1910.147(b). Do not treat an emergency stop, guard interlock, or maintenance mode as a substitute for the employer’s energy-control procedure.
The minor-servicing exception has specific conditions in 1910.147(a)(2)(ii). Whether it applies depends on the actual task and alternative protective measures; assess it against the standard rather than assuming an interlock creates an exception.
Writing procedures that fit automated cells
Document the applicable sources, isolation points, device use, stored-energy controls, and verification method required by 1910.147(c)(4), unless the narrow documentation exception applies. Use qualified personnel, authorized employees who perform the work, and manufacturer information to create and review the machine-specific instructions.
Tegis Safety can organize procedure fields, review, publication, QR access, and PDF export. It does not determine a safe isolation method, test equipment, or substitute for the employer’s assessment and approval. Coordinate outside servicing under 1910.147(f)(2), and review procedures when changes affect the equipment, energy sources, or work.
Frequently asked questions
Do we have to de-energize the robot completely?
Assess the task and equipment under the employer’s energy-control program. Where 1910.147 applies, use the employer-approved procedure to control each relevant energy source. A programmed pose or control mode is not, by itself, proof of isolation. Obtain the manufacturer’s instructions and qualified review for the actual cell.
How long do VFD capacitors hold a charge?
There is no universal time that applies to every drive. Follow the manufacturer’s instructions and employer-approved electrical safety procedure for the specific equipment. Do not infer that conductors are safe to touch from elapsed time alone; any testing must be performed by qualified personnel using the applicable method.
Does NFPA 70E or 1910.333 apply to electrical work here?
Electrical work may be subject to additional requirements, including 1910.333, depending on the task and exposure. The employer’s electrical safety program and qualified personnel must determine the applicable rules and test method. See OSHA 29 CFR 1910.333.
Do collaborative robots still need LOTO?
The label "collaborative" does not by itself determine whether 1910.147 applies or remove the need to assess servicing hazards. Evaluate the actual task, exposure, and equipment under the applicable OSHA standards and the employer’s energy-control program.
What about automatic restart after a power dip?
If a machine can restart when power or a control signal returns, include that behavior in the equipment assessment and employer-approved procedure. Do not rely on a stop command, interlock, or temporary pause as an energy-isolating device.