Lockout/tagout (LOTO) is the practice of isolating hazardous energy and locking or tagging the isolation points so a machine cannot start up while someone services or maintains it. In U.S. general industry, OSHA requires it under 29 CFR 1910.147.
Authorized employees follow the equipment-specific procedure, apply devices, control stored energy, and verify isolation before work begins. A written procedure supports that work; it does not replace training or the employer’s site-specific safety process.
Lockout vs. tagout: the difference
Lockout means placing a physical lock on every energy-isolating device (a disconnect switch, breaker, valve, or blank flange) so it cannot be operated. Tagout means attaching a warning tag that identifies who applied the device and why the equipment must not be operated.
A tag warns employees but does not physically restrain the energy-isolating device. OSHA requires lockout when the device can be locked, unless the employer demonstrates that tagout will provide full employee protection. If the device cannot be locked, the employer uses tagout and follows the standard’s tagout requirements.
What a lockout/tagout procedure actually contains
Under 1910.147(c)(4), a documented procedure must clearly outline its scope, purpose, authorization, rules, and techniques. The standard specifically requires the intended use, shutdown/isolation/securing steps, device placement/removal/transfer responsibilities, and testing requirements. OSHA Appendix A gives a non-mandatory example with equipment and energy-source details.
- The procedure’s intended use and the equipment or work it covers
- Specific steps to shut down, isolate, block, and secure the equipment
- Who places, removes, or transfers each lockout or tagout device
- How employees test and verify the effectiveness of the energy controls
- Equipment identifiers, energy sources, isolation points, and stored-energy controls needed for the site-specific procedure
Lockout/tagout devices and hardware
LOTO depends on physical hardware that holds an isolating device in the safe position. The core pieces are:
- Locks: padlocks (keyed alike for shared control, or keyed different so each employee has a unique key) that physically prevent operation of a disconnect, breaker, or valve. Each authorized employee carries their own, and only they hold its key.
- Tags: warning labels attached to a lock or device identifying who applied it and why. A tag warns; it does not physically stop energization.
- Hasps: multi-lock adapters that let several workers lock a single disconnect, so each person applies their own lock.
- Lockout stations: a board or cabinet holding the locks, tags, hasps, and device kits for a department, keeping everything standardized and in one place.
- Device-specific hardware: breaker lockouts, plug lockouts, ball-valve and gate-valve lockouts, cable lockouts, and group lockboxes for multi-worker jobs (see the group lockout guide).
Who is involved: authorized, affected, and other employees
OSHA divides employees into three roles. Authorized employees perform the service and apply the locks. Affected employees operate the equipment or work nearby and must understand when it is locked out. All other employees must simply know that locked-out equipment is never to be touched.
OSHA assigns training by role. Authorized employees learn the applicable energy sources and isolation methods; affected employees learn the purpose and use of the procedure; other employees in the area learn not to restart locked-out equipment.
Retraining is required after specified changes or when inspections or other information show a knowledge or use gap. The standard does not set a fixed annual retraining interval.
Why lockout/tagout matters so much
The standard covers servicing and maintenance where unexpected energization, startup, or release of stored energy could injure employees. The controls must account for the machine and task, including energy that can remain or build back up after shutdown.
OSHA publishes citation rankings and enforcement information by fiscal year. Use those official records for current figures; a ranking is not a prediction of risk at a particular facility.
Frequently asked questions
Is lockout/tagout required by law?
Yes. In the United States, OSHA standard 29 CFR 1910.147 requires employers to establish an energy control program with machine-specific procedures, training, and annual inspections for servicing and maintenance activities where unexpected energization could cause injury.
What are the six steps of lockout/tagout?
The standard sequence is: (1) notify affected employees, (2) shut down the equipment using its normal stopping procedure, (3) isolate every energy source at its disconnect point, (4) apply lockout devices and tags, (5) release or restrain stored and residual energy, and (6) verify zero energy before beginning work.
Does lockout/tagout apply to equipment you can just unplug?
The standard excludes cord-and-plug work only when the unexpected-energization hazard is controlled by unplugging and the plug stays under the exclusive control of the employee performing the service. Check for other hazardous energy and any other applicable standard before relying on this exclusion.
Can tagout be used instead of lockout?
OSHA requires lockout when the energy-isolating device can be locked, unless the employer demonstrates that tagout provides full employee protection. Tagout is used when the device cannot be locked, and tagout-only use has additional requirements and limitations.
What does LOTO stand for?
Lockout/tagout: sometimes written lock-out/tag-out. LOTO is the industry abbreviation for the OSHA energy control standard and the practices it requires. You will also see it called hazardous energy control, the formal name OSHA uses for 1910.147.
What is a lockout/tagout procedure?
A machine-specific, step-by-step document that tells an authorized employee exactly how to isolate every energy source on a piece of equipment, apply locks and tags, release stored energy, and verify zero energy before servicing. See our free lockout/tagout procedure template for the full structure.