LOTO is required when employees service or maintain machines where unexpected energization, start-up, or release of stored energy could injure them, unless the work falls under one of OSHA 1910.147’s scope exceptions.
This guide covers those exceptions: normal production, minor servicing, cord-and-plug equipment, hot-tap operations, and work governed by other standards. Assess the actual task and equipment against the regulation before deciding which requirements apply.
The trigger: servicing with exposure
Section 1910.147 applies to servicing and maintenance when unexpected energization, start-up, or release of stored energy could injure employees, unless a scope provision or exception applies. The rule defines servicing and maintenance and separately addresses normal production operations and minor servicing.
Hazardous energy may be electrical, mechanical, hydraulic, pneumatic, chemical, thermal, or another form. Determine whether the task is covered and whether a written procedure is required under 1910.147(c)(4); do not infer the answer from an energy label alone.
The minor servicing exception: narrow by design
Section 1910.147(a)(2)(ii) excludes minor tool changes and adjustments, and other minor servicing activities that take place during normal production operations, only when the work is routine, repetitive, integral to production, and effective alternative measures provide protection.
Evaluate each condition for the actual task and protective measures. Do not assume that a task qualifies because it is brief, frequent, or performed during production. If the exception does not apply and the work is within scope, follow the applicable energy-control requirements.
Cord-and-plug: exclusive control or full LOTO
Under 1910.147(a)(2)(iii)(A), the cord-and-plug exception applies when the equipment is unplugged and the plug remains under the exclusive control of the employee performing the servicing. Consider other energy sources and stored energy separately; a plug does not control hazards that it does not isolate.
The standard defines exclusive control to include the employee maintaining exclusive possession of the plug or exclusive control over it, such as keeping it in line of sight. Assess the actual setup and task against the rule; do not treat this summary as a case-specific determination.
Hot tap and scope boundaries
The hot-tap exclusion in 1910.147(a)(2)(iii)(B) is limited to hot-tap operations on pressurized transmission and distribution systems for specified fluids when continuity of service is essential, shutdown is infeasible, documented procedures are followed, and special equipment is used. Check every condition in the regulation.
Section 1910.147 is a general-industry standard with defined scope limits and exceptions. Other OSHA standards may apply depending on the industry, equipment, and work. For example, 1910.269 addresses certain electric power generation, transmission, and distribution work; 1910.333 covers electrical safety-related work practices. Confirm the governing requirements for the task.
How to decide on the floor
Review the task against 1910.147’s scope, the definition of servicing and maintenance, normal-production provisions, and each claimed exception. Consider the employee’s exposure, the energy sources, and the actual alternative protective measures.
Have the employer’s qualified safety personnel document the applicable decision and controls in the energy-control program. Use the checklist as a planning aid, not as a substitute for the standard or a task-specific assessment.
Frequently asked questions
Does clearing a jam require lockout/tagout?
It depends on the work, exposure, and equipment. If the task is covered servicing or maintenance, assess whether the minor-servicing exception in 1910.147(a)(2)(ii) applies; every listed condition, including effective alternative measures, must be met. A site-specific assessment is necessary.
If we just unplug it, is LOTO required?
The exception in 1910.147(a)(2)(iii)(A) applies when the equipment is unplugged and the plug is under the exclusive control of the employee performing the servicing. It does not control separate energy sources or stored energy; assess those hazards under the employer’s program.
Does 1910.147 apply to construction or electrical utilities?
Section 1910.147 is a general-industry standard. Other standards may apply to construction, electric power work, or electrical tasks. Check the applicable OSHA regulations for the actual industry, equipment, and work; do not assume that one cited standard covers every hazard.
What is the most misused LOTO exemption?
There is no single exception that is most commonly misused across all employers. The minor-servicing exception is one provision teams should assess carefully against each condition in 1910.147(a)(2)(ii).